Connection for DN 250 ISO-K with bracket screws, Connection for DN 250 ISO-F with retaining ring, Suitable for HiPace 1500 and 2300, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required
Connection for DN 100 CF-F-F, Suitable for HiPace 300 and 350, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required
Connection for DN 100 ISO-K with bracket screws, Connection for DN 100 ISO-F with retaining ring, Suitable for HiPace 300 and 350, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required
Connection for DN 40 ISO-KF with clamping ring, Suitable for HiPace 60/80, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required
Connection for DN 63 CF-F, Suitable for HiPace 60/80 and SplitFlow 50, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required
Connection for DN 63 ISO-K with bracket screws, Connection for DN 63 ISO-F with retaining ring, Suitable for HiPace 60/80 and SplitFlow 50, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required
Connection for DN 200 CF-F, Suitable for HiPace 800 and 1200, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required
Connection for DN 200 ISO-K with bracket screws, Connection for DN 200 ISO-F with retaining ring, Suitable for HiPace 800/1200/1800 and 800 M, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required
Connection for DN 160 CF-F, Suitable for HiPace 450, 700 and 700 M, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required