Cable for connection to TC 400/1200, TCP 350 and TM 700 included in the shipment, Venting mode, venting time and venting period adjustable via electronic drive unit and DCU/HPU, Connection G 1/8", Valve is normally closed, Connects with M12 plug directly to accessory outputs of electronic drive unit
Venting mode, venting time and venting period adjustable via electronic drive unit and DCU/HPU, G 1/8" connection, Valve is normally closed, Connects directly to TC 400, TC 1200 and TM 700
For BA 251 | BA 501, Venting valve for inlet side, Mounted at dome, Customer benefit: Prevents reverse turn of pump after switching pump off
Connection for DN 250 CF-F, Suitable for HiPace 1500 and 2300, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required
Connection for DN 250 ISO-K with bracket screws, Connection for DN 250 ISO-F with retaining ring, Suitable for HiPace 1500 and 2300, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required
Connection for DN 100 CF-F-F, Suitable for HiPace 300 and 350, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required
Connection for DN 100 ISO-K with bracket screws, Connection for DN 100 ISO-F with retaining ring, Suitable for HiPace 300 and 350, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required
Connection for DN 40 ISO-KF with clamping ring, Suitable for HiPace 60/80, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required
Connection for DN 63 CF-F, Suitable for HiPace 60/80 and SplitFlow 50, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required