Connection for DNย 250ย CF-F, Suitable for HiPace 1500 and 2300, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required
Connection for DNย 250ย ISO-K with bracket screws, Connection for DNย 250ย ISO-F with retaining ring, Suitable for HiPace 1500 and 2300, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required
Connection for DNย 100ย CF-F-F, Suitable for HiPace 300 and 350, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required
Connection for DNย 100ย ISO-K with bracket screws, Connection for DNย 100ย ISO-F with retaining ring, Suitable for HiPace 300 and 350, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required
Connection for DNย 40ย ISO-KF with clamping ring, Suitable for HiPace 60/80, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required
Connection for DNย 63ย CF-F, Suitable for HiPace 60/80 and SplitFlow 50, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required
Connection for DNย 63ย ISO-K with bracket screws, Connection for DNย 63ย ISO-F with retaining ring, Suitable for HiPace 60/80 and SplitFlow 50, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required
Connection for DNย 200ย CF-F, Suitable for HiPace 800 and 1200, For the employment of turbopumps on systems and plants that are sensitive to vibration, The flow resistance should be taken into account at the design of the pumping system, Only vertical operation allowed, Note: Fastening of the pump see operating instructions, An additional pump mounting is required