Relay box required to control backing pumps in conjunction with the TC 100 electronic drive units with TCS 10, TC 600, TC 750, TCP 350, TM 3000, The relay box with semiconductor relay is provided for intermittent operation on diaphragm vacuum pumps, The maximum relay contact load is 5 A
To control backing pumps connected with drive electronics TC 110/120 and TCP 350, 1-phase motor (e. g. rotary vane pumps) with a maximum of 20 A starting current, Can be directly connected with a M8 plug to the accessory outlets from the connection cable, TCS 12/13 as well as TC 110/120 with interface (PB, E74, RS), With accessory cable, can be connected to TCP 350, Control lead (0.45 m) included in scope of delivery
For controlling backing pumps in conjunction with electronic drive unit TC 400 and TCP 350, 1-phase motor (e. g. rotary vane pumps) with a maximum of 20 A starting current, Connects with M12 plug directly to TC 400, With accessory cable, can be connected to TCP 350, Control lead (0.45 m) included in scope of delivery
To control backing pumps connected with drive electronics TC 110 and TCP 350, 1-phase motor (e. g. rotary vane pumps) with a maximum of 20 A starting current, Can be directly connected with a M8 plug to the accessory outlets from the connection cable, TCS 12/13 as well as TC 110 with interface (PB, E74, RS), With accessory cable, can be connected to TCP 350, Control lead (0.45 m) included in scope of delivery
To control backing pumps connected with drive electronics TC 400/1200, TM 700 and TCP 350, 1-phase motor (e. g. rotary vane pumps) with a maximum of 20 A starting current, Can be directly connected with M12 to TC 400/1200 and TM 700, With accessory cable, can be connected to TCP 350, Control lead (0.45 m) included in scope of delivery
To control backing pumps connected with drive electronics TC 400/1200, TM 700 and TCP 350, 1-phase motor (e. g. diaphragm pumps) with a maximum of 7A startup current, Can be directly connected with M12 to TC 400/1200 and TM 700, With accessory cable, can be connected to TCP 350, Control lead (0.45 m) included in scope of delivery
To control backing pumps connected with drive electronics TC 110/120 and TCP 350, 1-phase motor (e. g. diaphragm pumps) with a maximum of 7A startup current, Can be directly connected with a M8 plug to the accessory outlets from the connection cable, TCS 12/13 as well as TC 110/120 with interface (PB, E74, RS), With accessory cable, can be connected to TCP 350, Control lead (0.45 m) included in scope of delivery
Don't worry we won't leave you in a vacuum