High-performance Roots pump with a pumping speed of 590 to 1420 m3/h, Blocked overflow valve, For operation with frequency converter or switch-on at a defined backing pressure, i.e. for continuous processes, With 3-phase motor II 2G Ex de IIC T4, Pumps are hermetically sealed (leak rate <1 · 10-6 Pa m3/s) – risk of zone entrainment is minimized, Pressure surge resistance according to EN 1333, PN level 16, Explosion safety due to reliable construction and temperature monitoring – installation without additional flame arrester possible, Note: For the operation of the pumps, the terms of the operating instructions apply. We are pleased to provide you with the right solution for your application!, Working conditions: Pump is inside and outside suitable for operation in equipment class II, equipment category 3 (G) for gases and vapors of explosion class IIA and IIB, temperature class T3 according directive 2014/34/EU
High-performance Roots pump with a pumping speed of 590 to 1420 m3/h, PTFE overflow-valve (Δp = 30 hPa), No thermal overload thanks to integrated overflow valve, With 3-phase motor II 2G Ex de IIC T4, Pumps are hermetically sealed (leak rate <1 · 10-6 Pa m3/s) – risk of zone entrainment is minimized, Pressure surge resistance according to EN 1333, PN level 16, Explosion safety due to reliable construction and temperature monitoring – installation without additional flame arrester possible, Note: For the operation of the pumps, the terms of the operating instructions apply. We are pleased to provide you with the right solution for your application!, Working conditions: Pump is inside and outside suitable for operation in equipment class II, equipment category 2 (G) for gases and vapors of explosion class IIA and IIB, temperature class T3 according directive 2014/34/EU
High-performance Roots pump with a pumping speed of 590 to 1420 m3/h, Blocked overflow valve, For operation with frequency converter or switch-on at a defined backing pressure, i.e. for continuous processes, With 3-phase motor II 2G Ex de IIC T4, Pumps are hermetically sealed (leak rate <1 · 10-6 Pa m3/s) – risk of zone entrainment is minimized, Pressure surge resistance according to EN 1333, PN level 16, Explosion safety due to reliable construction and temperature monitoring – installation without additional flame arrester possible, Note: For the operation of the pumps, the terms of the operating instructions apply. We are pleased to provide you with the right solution for your application!, Working conditions: Pump is inside and outside suitable for operation in equipment class II, equipment category 2 (G) for gases and vapors of explosion class IIA and IIB, temperature class T3 according directive 2014/34/EU
High-performance Roots pump with a pumping speed of 590 to 1420 m3/h, PTFE overflow-valve (Δp = 30 hPa), No thermal overload thanks to integrated overflow valve, With 3-phase motor II 2G Ex de IIC T4, Pumps are hermetically sealed (leak rate <1 · 10-6 Pa m3/s) – risk of zone entrainment is minimized, Pressure surge resistance according to EN 1333, PN level 16, Explosion safety due to reliable construction and temperature monitoring – installation without additional flame arrester possible, Note: For the operation of the pumps, the terms of the operating instructions apply. We are pleased to provide you with the right solution for your application!, Working conditions: Pump is inside and outside suitable for operation in equipment class II, equipment category 3 (G) for gases and vapors of explosion class IIA and IIB, temperature class T3 according directive 2014/34/EU
Don't worry we won't leave you in a vacuum